https://doi.org/10.1140/epja/s10050-022-00720-y
Regular Article - Experimental Physics
Determination of (n,2n) reaction cross-section for 154Sm, 150Nd and 82Se at 14.6 MeV neutron energy
1
Radiochemistry Division, Bhabha Atomic Research Centre, 400085, Mumbai, India
2
Homi Bhabha National Institute, Anushaktinagar, 400094, Mumbai, India
3
Nuclear Physics Division, Bhabha Atomic Research Centre, 400085, Mumbai, India
4
Technical Physics Division, Bhabha Atomic Research Centre, 400085, Mumbai, India
Received:
9
November
2021
Accepted:
31
March
2022
Published online:
30
April
2022
The (n,2n) reaction cross-sections of 154Sm, 150Nd and 82Se isotopes at 14.6 MeV neutron energy have been measured by neutron activation followed by off-line gamma-ray spectrometry with improved experimental methodology. The neutron flux was determined using the 197Au(n, 2n)196Aug monitor reaction which has not been used earlier for cross-section measurement for the above mentioned nuclei. The measured reaction cross-sections are found to have good agreement with calculated cross-section data, obtained independently, using Talys and ENDF codes. A detailed comparison of the present cross-section data with the existing literature has been presented in this paper.